Overview

As with all adapters, an existing https://unit040.atlassian.net/wiki/spaces/PUD/pages/280987237/Logic+Simulator#Overview is required.

...

Where to find the different Gateway Adapters.

...

Where to find

To find the Active MQ adapter, go to the Inspector window of a https://unit040.atlassian.net/wiki/spaces/PUD/pages/280987237/Logic+Simulator#Overview component.
This https://unit040.atlassian.net/wiki/spaces/PUD/pages/280987237/Logic+Simulator#Overview can be added under Logic.

...

Feature overview

...

 

Info

Only the settings between the lines refer to the Active MQ Adapter.

...

Gateway settings

Adapter Target

Select a different adapter, please see respective documentation for more information

Adapter Setting (MQTTServerSettings)

XmlFilePath

File path to the policy file

Note

Warning : <Make sure to fill in a relative path to the Asset folder of the project and include .xml file extension>

ServerName

Is used as the an indicator in the XML policy file

IP Address

The address of the ActiveMQ server. This can be a be in IPv4 address or a hostname like localhost

Port

The port on which the ActiveMQ broker is running, the default port is 61616.

CorrelationID

The identifier on which a message responds. Different Correlation IDs can communicate over the same queue, but is not recommended. Make sure other clients use the same Correlation ID

DeliveryMode

Int that defines whether the message is persistent(0) or non_persistent(1).

Persistent is default and makes sure the message survives a broker reset. It can be a slower than non_persistent

Lifecycle settings

Note

Not implemented for Active MQ

...

Prerequisites

ActiveMQ can work with an online broker on the internet, but is more commonly used with a local broker. A local broker can be downloaded from the Apache Website: https://activemq.apache.org/components/classic/download/

...

In the admin panel you will find an overview of the current queues and its connected consumers and producers when you click on ‘Queues’.

...

Used Protocol

To communicate with the ActiveMQ adapter in prespective you need to have to apply the following protocol:

...

  • Destination = queue as defined in plc address

  • CorrelationID = same as defined in ActiveMQ adapter settings

...

Supported Types

  • BOOL

  • BYTE

  • SBYTE

  • WORD

  • DWORD

  • SHORT

  • USHORT

  • INT16

  • UINT16

  • INT32

  • UINT32

  • INT64

  • UINT64

  • REAL32

  • REAL64

  • BYTEARRAY

  • STRING

  • STRUCT

...

Naming Rules