V2020.1.56.3_ OPC UA



Overview

As with all adapters, an existing Logic SimulatorUNDEFINED is required.

Where to find the different Gateway Adapters


Where to find

To find the OPC UA adapter, go to the Inspector window of a V2020.1.56.3_ Logic Simulator | Overview component.
This V2020.1.56.3_ Logic Simulator | Overview can be added under Logic.


Feature overview

Only the settings between the lines refer to the OPC UA Adapter.

Please check the documentation for the rest of the V2020.1.56.3_ Logic Simulator | Overview

Gateway settings

 

Gateway settings

 

Adapter Target

Select a different adapter, please see prespective documentation for more information

Adapter Setting (OPCUAServerSettings)

 

XmlFilePath

File path to the policy file

Warning : <Make sure to fill in a relative path to the Asset folder of the project and include .xml file extension>

endPointURL

The endpoint of the server

configurationFilePath

Configuration path for the configuration XML (default is sample case, please use your own)

namespaceIndex

the namespace index for opc ua

IdentifierTypeOpc

The identifier type for this configuration

For more information:

http://documentation.unified-automation.com/uasdkhp/1.0.0/html/_l2_ua_node_ids.html

UserName

Is passed to the server for authentication if the field is not empty (not used by default)

PassWord

Is passed to the server for authentication when the UserName field is not empty (not used by default)


Fidelity:

In order to get opc variables in real-time the fidelity of the signal definition has to be set to 0.

To use a subscription set the fidelity to the number of seconds for the interval.

Default fidelity is -1 this is counted as 1.


Right now we do not offer support for certificate accepting within Unity. A quick workaround is to connect to the server via Ua Expert and accept the certificate there. Then it should also work in prespective.

https://www.unified-automation.com/products/development-tools/uaexpert.html


 

Opc ua variable naming

For the naming of opc ua variables we have to create the NodeId.

https://documentation.unified-automation.com/uasdkhp/1.0.0/html/_l2_ua_node_ids.html

Example NodeId:

ns=4;i=1241

for this example, you have to configure your PreLogic Simulator as follows:

And your PrelogicComponent:

(Example Script)

public class OPCTestComponent : PreLogicComponent { public override List<SignalDefinition> SignalDefinitions => new List<SignalDefinition> { new SignalDefinition("1241", PLCSignalDirection.INPUT, SupportedSignalType.BOOL), }; }

 

Another example NodeId (Tia Portal):

ns=3;s="OPC_UA_DB"."TestBOOLINPUT0"

for this example, you have to configure your PreLogic Simulator as follows:

And your Prelogic component:

(Example Script)

public class OPCTestComponent : PreLogicComponent { public override List<SignalDefinition> SignalDefinitions => new List<SignalDefinition> { new SignalDefinition("TestBOOLINPUT0", PLCSignalDirection.INPUT, SupportedSignalType.BOOL), }; }

 

Prespective Documentation